Features:
- Supply Voltage: 90-305Vac or 127-420Vdc
- Great Surge Immunity 10kV
- -55℃Cold Ambient Startup (Optional)
- 100,000Hour Life @ Tc=75℃
- 7 Year Warranty @ Tc<=75℃
- 0-10V/PWM/Time/DALI/DMX (RDM) Dimmable
- Dim Off with 0.5W Standby Power
- 12V 300mA Auxiliary Power to Power Controllers and Fans (Model Depending)
- Class II Model Available
- UL Class P, Class 2
- SELV Output, safety according to EN 61347-1, 61347-2-3, 61347-2-13, 62384
Technical Data :
- Input Voltage: 90~305Vac or 127V-420Vdc
- Input Frequency: 47~63Hz
- Power Factor: >0.9@60-100%load, refer to PF vs. Load curve
- THD: <15%@60-100%load, refer to THD vs. Load curve
- Input Current: 0.8Amax@120Vac & Full-Load, 0.4Amax@220Vac & Full-Load
- Inrush Current: 65A peak, 1.2ms duration, <0.25A2s@230Vac, Cold Start; 70A peak, 1.3ms duration, <0. 5A2s@277Vac, Cold Start
- Leakage Current: 1mA max @277Vac 60Hz, UL8750,0.75mAmax @220Vac 50Hz, IEC61347-1
- Input Under Voltage: Shut down and auto-restart
- Input Over Voltage: *Optional: Shutdown @320Vac
- Surge Protection: Line to line 6kV, line to ground 10kV, IEC 61000-4-5
- Current Accuracy: ±5%Io
- Ripple Current: Ip-p:5%Io max
- Setup Time: 1.2s max
- Overshoot: 10% Io max & LED Load
- Output Over Voltage: 120% Vomax, typ.
- Short Circuit: Auto recovery. The output recovers when short is removed
- Over Temperature: Lower the output current when Tc≧105±10℃; Auto recovery when Tc≦70±10℃
- Auxiliary Power (Vaux) : 12V+/-5%, 300mA max
- Operating Temperature: -40℃~+70℃ ;10%RH~100%RH
- Storage Temperature: -40℃~+85℃; 5%RH~100%RH
- MTBF: ≥320,000 hours, 75℃ case temperature (MIL-HDBK-217F)
- Lifetime: ≥100,000 hours, 75℃ case temperature, refer to life vs. Tc curve
- Case Temperature: 90℃ max, marked in the Tc point of label
- Dimensions: 10.72x1.41x1.18 by inch (body), 11.33x1.41x1.18 by inch (endcaps included); 272.4x36x30 by mm (body), 288.0x36x30 by mm (endcaps included)
- Net Weight: 650g
- Packing: TBD
Notes: Unless specified, all the test results are measured in 25℃ room temperature.
* marked items are optional and contact with sales people to get the functions.
Production Lead Time
7 days